- Radical-7 Signal Extraction Pulse CO-Oximeter Operator’s Manual i The Radical-7 Pulse CO-Oximeter Operating Instructions provide the necessary information for proper operation of all models of the Radical-7 Pulse CO-Oximetry system. There may be information provided in this manual that is not relevant for your system.
- Pulse CO-Oximeter User ManualLAB-10107CRedlines details for FCC ID VKF-RAD7B made by Masimo Corporation. Document Includes User Manual Operator's Manual, Radical-7.
One moment please..
- Parts
- Videos
- News
DESCRIPTION
Providing upgradable rainbow® technology in multiple configurations for maximum clinical flexibilityThe Radical-7 leverages Masimo's noninvasive measurements with functionality designed to automate the process of care and enable clinicians to adapt to changing monitoring needs in individual patients and care areas.
Choose the noninvasive measurements that are right for your clinical setting—oxygen saturation, pulse rate, and perfusion index in addition to total hemoglobin, total arterial oxygen content, pleth variability index, carboxyhemoglobin, methemoglobin, and acoustic respiration rate.
Choose the noninvasive measurements that are right for your clinical setting—oxygen saturation, pulse rate, and perfusion index in addition to total hemoglobin, total arterial oxygen content, pleth variability index, carboxyhemoglobin, methemoglobin, and acoustic respiration rate.
Masimo Radical 7 User Manual Pdf File
FORUMSView All (10)
Qualified operator may perform maintenance procedures specifically described in this manual. Refer servicing to Masimo for repair of this equipment. Smoke alarm movie. Rad-57 Signal Extraction Pulse CO-Oximeter Operator’s Manual iii Safety Information, Warnings and Cautions, continued. The user is encouraged to try to correct the interference by one.
Ask a New Question
1Reply7 months ago | 7 months agoHard Reset I have found that many miscellaneous issues such as touchscreen problems can be resolved by performing a hard reset on this device. This is performed by pushing the power button once. Wait for the Masimo logo to appear, then press and hold the power button again. Continue holding the power button until you hear a double beep and then release. Reply |
-rcderek22 2 years ago | 2 years agoService watchdog One of our Radical 7's is showing a Service watchdog error then unsuccessfully attempts to power itself off. Has anybody else seen that? Is there any way to repair these without sending them in? Thanks-DerekReply |
0Replies2 years ago | 2 years agoSetting output to ASCII-2 for download data On my Radical 7 the output selection format in Data output menu has only one choice, 'Data collection' (that, by the way, I don't understand). To download data with the TrendCome program, i need to set this to ASCII-2, but I can't.Any hint?Reply |
DOCUMENTS / MANUALSView All
User Manual Pdf Download
FEATURES
- Intuitive Operation - Quick touch, drag, and drop. Clinicians can move any parameter to and from center and bottom of the display, never losing track of any vital signs
- Adaptable Functionality - Standalone device; Detachable, battery-operated wireless device; Handheld or wearable
- Integrated Wireless Connectivity - Keeps patients connected even while they are ambulating to enable clinician notification and automate charting and enable meaningful use of electronic health record systems
- Powerful Clinical Applications - Operating Room, PACU, ICU, Medical-Surgical Care, Neonatal Intensive Care, Newborn Screening, Emergency and Respiratory Care
SPECIFICATIONS
Memory | 72 hr |
Operating Life | 10 hr |
Pulse Rate Range | 25-240 BPM |
SpO2 Range | 0-100% |
Weight | 1.2 lbs |